Distributor

Critical Care

Ambulatory NIBP Monitor KABM-A100

Patient range Adult, pediatric, neonate
NIBP Measurement method Oscillometric
NIBP Measurement range 0 kPa – 38.67 kPa (0 mmHg – 290 mmHg)
NIBP Measurement mode Arm Measurement

Blood and Infusion Warmer KBIW-A100

Temperature Range 37°C to 42°C
Temperature Accuracy ± 0.5°C
Warm-up Time < 45 s (20°C to 36°C)
Power Consumption 250 VA

Blood and Infusion Warmer KBIW-A200

Temperature Range 37°C to 42°C
Temperature Accuracy ± 1.0°C
Warm-up Time < 45 s (20°C to 36°C)
Power Consumption 80 VA

Fetal Monitor KCTG-A100

Display 12.1” LCD display
Ultrasound frequency 1024 (1 ± 10%) kHz
Max output intensity < 10 MW/cm2
FHR measurement range 30 bpm ~ 240 bpm

Defibrillator Monitor KDM-A100

Display 7-inch screen
Waveform Biphasic
Manual with Sync mode 2, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 300, 360 joules
AED mode Auto analyze and charge x 3 with programmable auto energy level selection.

Automated External Defibrillator KED-A100

Waveform Biphasic
Energy Sequence 150 J, 200 J
Analysis Time 9 seconds
Audio Indications 20 distinct voice instructions

Holter Monitor KHM-A100

Display OLED 160 x 128 dot matrix display
Storage Built-in TF card storage for up to 2 GB
Standard Sensitivity 10 mm/mV ± 5%
Sensitivity Shift ≤ ± 10%

Infant Incubator KII-A100

Control System Air-temp control, Skin-temp control & Humidity control
Display LED display
Air Temperature Control range 25°C ~ 37°C (Override : 37°C ~ 39°C)
Baby Temperature Control range 25°C ~ 37°C (Override : 37°C ~ 39°C)

Infant Incubator KII-A101

Control System Air-temp control & Skin-temp control
Display LED display
Air Temperature Control range 25°C ~ 37°C (Override : 37°C ~ 39°C)
Baby Temperature Control range 25°C ~ 37°C (Override : 37°C ~ 39°C)

Infant Incubator KII-A102

Control System Air-temp control
Display LED display
Air Temperature Control range 25°C ~ 37°C
Baby Temperature Control range

Infusion Pump KIP–A100

Channel Single channel infusion
Volume (VTBI) 1 ml ~ 9999.9 ml ( 0.1 ml increment)
Accuracy Flow rate: ≤ ± 3 %
Mechanical: ≤ ± 2 %
KVO Rate 1 ml/h (1 ml/h ~ 300 ml/h)
3 ml/h (greater than 300 ml/h)

Infusion Pump KIP–A101

Channel Single channel infusion
Infusion Volume 0 ml ~ 9999 ml ( 0.1ml increment)
Infusion Rate 0.01 ml/h ~ 1200 ml/h (0.01ml/h increment)
KVO Rate 0.01 ml/h – 5 ml/h

Intensive Care Ventilator KIV-A101

Tidal Volume 20 ml ~ 500 ml
Standard Ventilation Mode VCV, SIMV, PSV, PCV, CPAP, Manual, SIGH
Application Adult/ Pediatric Invasive
Pressure Range 5 mbar ~ 80 mbar

Intensive Care Ventilator KIV-A102

Tidal Volume 10 ml ~ 300 ml
Standard Ventilation Mode CMV, IMV, CPAP, Manual
Application Pediatric
Inspiratory Flow 3 L/min ~ 20 L/min

Intensive-Care Ventilator KIV-A200

Tidal Volume 20 ml ─ 2500 ml
Configurations Trolley or Ceiling Pendant
Respiratory Rate 1 bpm ─ 40 bpm (V-SIMV/P-SIMV/PRVC-SIMV)
4 bpm ─ 100 bpm ( VCV/PCV/PRVC)
Psupport 0 kPa ─ 6 kPa

Infant Warmer KIW-A100

Control System Microprocessor based temperature control system
Control Modes Preheat, Manual and Skin-temp mode
Manual : Heater output 0-100%, 10% increments
Skin-temp : Control range 25 °C ~ 37 °C

Vital Sign Monitor KPM-A100

Vital Parameters
Type AType BType C
4 Parameters (NIBP,SpO2, PR, Temp)3 Parameters (SpO2, PR, Temp)3 Parameters (NIBP, SpO2, PR)
Display 240 x 320 dot matrix colour TFT
NIBP Measurement range Adult: 30-255 mmHg
Paediatric: 30-160 mmHg 
NIBP Mode Auto, Manual, STAT

Vital Sign Monitor KPM-A200

Vital Parameters 3 Parameters (SpO2 (with PR), NIBP, & 1-channel TEMP)
NIBP Measurement range Systolic Adult 50 ~ 265 mmHg Child 25 ~ 135 mmHg Diastolic Adult 15 ~ 220 mmHg Child 12 ~ 110 mmHg MAP Adult 25 ~ 245 mmHg Child 18 ~ 120 mmHg
NIBP Mode Manual, Auto
NIBP Parameters Sys, Dia, MAP

Multi-para Monitor KPM-B100

Standard Parameter 5‐lead ECG, RESP, HR, NIBP, SpO2(F‐5), 1‐TEMP, PR
Patient Groups Neonate, Pediatric, Adults
Trace 9 waveform (ECG,SpO2, RESP)
ECG Lead Mode 5–lead (R, L, F, N, C) for leads I, II, III, V, aVR, aVF, aVL

LED Phototherapy System KPT-A100

Light Source 8 Blue LED lights
Wavelength 450 to 475nm
LED Lamp-life 1,00,000 hours
Intensity Control Low : 25 ~ 35 μW /cm2/nm
High : 35 ~ 55 μW /cm2/nm

Resuscitator KRE-A100

Type Adult
Stroke volume 800 ml
Resuscitator volume 1630 ml
Bag reservoir volume 2000 ml

Resuscitator KRE-A101

Type Pediatric
Stroke volume 350 ml
Resuscitator volume 680 ml
Bag reservoir volume 1600 ml

Resuscitator KRE-A102

Type Neonatal
Stroke volume 150 ml
Resuscitator volume 250 ml
Bag reservoir volume 600 ml

Syringe pump KSP-A100

KVO Rate 0.1 – 5ml/h (steps : 0.1ml/h)
Injection Compliance Adaptable for 5 syringe sizes
Preset Volume Range 0.1 ml – 1999.9 ml
Occlusion System 3-level alarming system

Syringe pump KSP–A200

Channel Single channel infusion
Volume (VTBI) 0 ml – 9999 ml
Injection Compliance Adaptable for 6 syringe sizes
Accuracy ≤ ±2 %

Syringe pump KSP–B100

Channel Dual channel infusion
Volume (VTBI) 0.1 ml – 1999.9 ml
Injection Compliance Adaptable for 10 syringe sizes
Accuracy ≤ ± 3 %

Transport Ventilator KTV-A100

Tidal Volume 0 ml – 1500 ml
Gas Supply O2, 0.28 to 0.6 MPa
Ventilation Modes A/C, SIMV, SPONT, Manual, VCV+SIGH
Respiratory Rate 4 bpm – 40 bpm (SIMV)
4 bpm – 99 bpm (A/C)