Distributor

Laboratory Analyser

Chemistry Analyser KCA-A200

Type Fully Automated Analysis system
Throughput 140 tests per hour
Analytical Methods End point, Kinetic, fixed time, Bi-chromatic, multi-standard, Two steps of end point and more
Assay Modules Over 200 modules

Chemistry Analyser KCA-A201

Type Fully Automated Random Access System
Throughput Reagent 1 : 400 test/hr
Reagent 2 : 600 test/hr
With ISE : 400 test/hr
Analytical Methods End-point, Multi-standard, Immuno-turbid metric, 1-2 reagent, Reagent/serum blank, etc.
Assay Modules 80 modules

Chemistry Analyser KCA-A202

Type Fully Automatic Random Access system
Throughput 120 tests/hour
Assay Modules Up to 26 Assays
Sample slots 9

Coagulation Analyser KCG-A100

Number of channels Single channel
Test parameters PT [Prothrombin Time]
APTT [Activated Partial Thromboplastin Time]
TT [Thrombin Time]
FBG [Fibrinogen Concentration]
Clotting Factors
Measurement method Photometric analysis
Display Back-illuminated LCD

HbA1c analyzer KGH-A100

Measurement range 3 % ~ 18 %
Testing parameters Precision (CV) < 3 %
Accuracy (V) < 1.5 %
Sample type Venous blood (EDTA anticoagulation), Peripheral finger blood
Sample volume 5 µl whole blood for each sample

Haematology Analyser KHA-A100

Type Fully automated 3-part differential system
Throughput 60 samples/hr
Principle of Operation
Testing Parameters WBC, LYM#, MON#, GRA#, LYM%,MON%, GRA%, RBC, HGB, MCHC, MCH, MCV, PDW, RDW-CV, RDW-SD, HCT, PLT,MPV, P-LCR, PCT with Histograms for WBC, RBC and PLT.

Haematology Analyser KHA-A101

Type Fully automated 3-part differential system
Throughput 60 samples/hr
Principle of Operation
Testing Parameters WBC, LYM#, MON#, GRA#, LYM%,MON%, GRA%, RBC, HGB, MCHC, MCH, MCV, PDW, RDW-CV, RDW-SD, HCT, PLT,MPV, P-LCR, PCT with Histograms for WBC, RBC and PLT.

Haematology Analyser KHA-A200

Type Fully automated 3-part differential system
Throughput 60 samples/hr
Principle of Operation
Testing Parameters WBC, LY, LY%, MO, MO%,GR,GR%,RBC,HGB,HCT, MCV,RDW-SD, RDWCV, MCH, MCHC, PLT, MPV, PCT, PDW with Histograms for WBC, RBC and PLT.

Haematology Analyser KHA-B100

Type Fully automated 5-part differential system
Throughput 60 samples/hr
Principle of Operation
Testing Parameters WBC, RBC, HGB. HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, PDW, MPV, PCT, P-LCR, NEU#, NEU%, LYM#, LYM%, MON#, MON%, EOS#, EOS%, BAS#, BAS%, ALY#, ALY%, IG#, IG%, 2 histograms, 2 scatter grams.

Veterinary Haematology Analyser KHA-C100

Type Fully automated 3-part differential system
Throughput 30 samples/hr
Principle of Operation Impedance, SFT method
Testing Parameters

Veterinary Haematology Analyser KHA-C101

Type Fully automated 5-part differential system
Throughput 60 samples/hr
Principle of Operation Impedance, Colorimetry
Testing Parameters

Urine analyzer KUA-A100

Method RGB Tricolor test
Test mode Single-step test
Strip compliance 8, 10, 11, 12, 14 parameter test strips
Memory Stores up to 500 records